Conductivity Range 0 to 20.00, 200.0, 2000 µS/cm;
20.00, 200 mS/cm
TDS Range 0 to 10.00, 100.0, 1000 ppm;
10.00, Max. 100 ppt (depending on factor setting)
Resolution 0.05% of Full Scale
Accuracy ± 1% Full Scale + 1 LSD
Temperature Range -10.0 to 110.0 °C (14.0 to 230 °F) (Meter)
Resolution & Accuracy 0.1 °C & ± 0.5 °C (0.9 °F)
Calibration for Conductivity Automatic (single or multi-point up to 4 points) / Manual (up to 5 points)
Calibration for TDS Manual (up to 5 points – 1 per range)
Normalization Temperature 15.0 to 30.0 °C
Cond. to TDS Conversion Factor 0.40 to 1.00 (selectable)
Cell Constant 0.1, 1.0 or 10.0 (selectable)
Temperature Coefficient 0.0 to 10.0 %/°C (adjustable)
Memory 50 Data Sets
Special Functions Auto-ranging; Auto-calibration, Auto-hold;
Stability Indicator & Self-diagnostic
Power 9VDC, using AC adapters 110VAC or 220VAC, 50/60 Hz

Order Information

Order No.

Item
ECCON51013S CyberScan CON 510 Bench Conductivity / TDS Meter with Conductivity electrode (ECCONSEN91W), integral electrode holder & 110 VAC power adapter
ECCON51023S CyberScan CON 510 Bench Conductivity/TDS Meter with Conductivity electrode (ECCONSEN91W), integral electrode holder & 220 VAC power adapter
ECCONSEN91W 2 Stainless Steel Rings Ultem-body Electrode with ATC, cell constant K=1.0, 16×110 mm, 6-pin connector, 1 m cable length (for CON 510)
ECCONSEN72W Glass body 2-cell Conductivity Electrode with ATC, cell constant K=0.1, DIN connector, 1 m cable length

 

Deskripsi

Jual ALat Ukur Eutech Economy / Deluxe Bench Model CyberScan CON 510

Deskripsi Eutech Economy / Deluxe Bench Model CyberScan CON 510

Alat Ukur Laboratorium Eutech

Aplikasi

Pengujian Rutin: Untuk pemeriksaan konduktivitas atau TDS yang cepat dan akurat di laboratorium, lapangan, dan sekolah. Berguna dalam industri hidroponik dan pertanian.

Industri: Untuk pengecekan finishing logam, air menara pendingin, solusi air mancur pencetakan, air boiler, brines, lumpur pengeboran, tangki peningkat, kolam, pengendalian polusi, sistem resirkulasi, air limbah dan sistem proses industri.

Pengujian Kualitas Air: Untuk menganalisis air sadah, air yang tidak diolah, air minum, air limbah, air kolam dan air proses yang masuk. Ideal untuk semua jenis jaminan kualitas dan pengujian kualitas air.

Specifications

Product Specification Description
Conductivity Range 0 to 20.00, 200.0, 2000 µS/cm;
20.00, 200 mS/cm
TDS Range 0 to 10.00, 100.0, 1000 ppm;
10.00, Max. 100 ppt (depending on factor setting)
Resolution 0.05% of Full Scale
Accuracy ± 1% Full Scale + 1 LSD
Temperature Range -10.0 to 110.0 °C (14.0 to 230 °F) (Meter)
Resolution & Accuracy 0.1 °C & ± 0.5 °C (0.9 °F)
Calibration for Conductivity Automatic (single or multi-point up to 4 points) / Manual (up to 5 points)
Calibration for TDS Manual (up to 5 points – 1 per range)
Normalization Temperature 15.0 to 30.0 °C
Cond. to TDS Conversion Factor 0.40 to 1.00 (selectable)
Cell Constant 0.1, 1.0 or 10.0 (selectable)
Temperature Coefficient 0.0 to 10.0 %/°C (adjustable)
Memory 50 Data Sets
Special Functions Auto-ranging; Auto-calibration, Auto-hold;
Stability Indicator & Self-diagnostic
Power 9VDC, using AC adapters 110VAC or 220VAC, 50/60 Hz

Order Information

Order No.

Item
ECCON51013S CyberScan CON 510 Bench Conductivity / TDS Meter with Conductivity electrode (ECCONSEN91W), integral electrode holder & 110 VAC power adapter
ECCON51023S CyberScan CON 510 Bench Conductivity/TDS Meter with Conductivity electrode (ECCONSEN91W), integral electrode holder & 220 VAC power adapter
ECCONSEN91W 2 Stainless Steel Rings Ultem-body Electrode with ATC, cell constant K=1.0, 16×110 mm, 6-pin connector, 1 m cable length (for CON 510)
ECCONSEN72W Glass body 2-cell Conductivity Electrode with ATC, cell constant K=0.1, DIN connector, 1 m cable length