Jual Digital Multimeter Fluke 115

Specifications: Fluke 115 Field Technicians Digital Multimeter

Specifications
Accuracy Specifications
DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2
Diode test Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/resolution > 1000 μF
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
AC amps True RMS
(45 Hz to 500Hz)
Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A overload for 30-seconds max
DC amps Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2 Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50.00 kHz / 0.01 kHz
Accuracy 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.

 

General Specifications
Maximum voltage between any terminal and earth ground 600 V
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10℃ to + 50℃
Storage temperature -40℃ to + 60℃
Battery type 9 volt Alkaline, IEC 6LR61
Battery life 400 hours typical, without backlight
Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight 550 g
Warranty 3 years

Deskripsi

Jual Digital Multimeter Fluke 115

Deskripsi Fluke 115 Digital Multimeter

Fluke 115 Digital Multimeter
Multimeter digital True-rms ringkas untuk layanan lapangan
Termasuk: meteran, sarung, set uji silikon 4 mm
Pengoperasian meteran yang mudah dengan satu tangan
Min / Maks / Rata-Rata untuk merekam fluktuasi sinyal

Fluke 115 Teknisi Lapangan Multimeter Digital
Compact true-rms meter untuk teknisi servis lapangan
Multimeter digital teknisi lapangan Fluke 115 mengukur tegangan dan arus True-rms dengan resistansi plus, kontinuitas, frekuensi, dan kapasitansi untuk memenuhi kebutuhan beragam teknisi layanan lapangan.

115 multimeter digital menawarkan operasi satu tangan dan layar backlit. Digit yang besar dan mudah dibaca menawarkan resolusi 6000 hitungan. 115 memberi Min / Max / Average waktu berlalu untuk merekam fluktuasi sinyal. Ini juga mengukur:

Tegangan AC dan DC ke 600V,
Arus AC dan DC ke 10 A (kelebihan 20 A selama 30 detik maks).

Specifications: Fluke 115 Field Technicians Digital Multimeter

Specifications
Accuracy Specifications
DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2
Diode test Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/resolution > 1000 μF
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
AC amps True RMS
(45 Hz to 500Hz)
Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A overload for 30-seconds max
DC amps Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2 Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50.00 kHz / 0.01 kHz
Accuracy 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.

 

General Specifications
Maximum voltage between any terminal and earth ground 600 V
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10℃ to + 50℃
Storage temperature -40℃ to + 60℃
Battery type 9 volt Alkaline, IEC 6LR61
Battery life 400 hours typical, without backlight
Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight 550 g
Warranty 3 years