Jual Direct Soil Measurement pH Portable Meter Hanna – HI99121
SPESIFIKASI : Direct Soil Measurement pH Portable Meter Hanna – HI99121
DETAIL
Features at-a-glance
- Automatic Temperature Compensation
- One or two-point automatic calibration
- BEPS – Alerts the user of low battery power that could adversely affect readings
- Compact, heavy-duty, and waterproof
- Battery % displayed on start-up
- HELP feature, displays messages on LCD
Note: Use the soil auger for stony ground to prevent damaging the glass probe.
For high accuracy and ensure the soil is wet use the HI7051M soil preparation solution.
For high accuracy and ensure the soil is wet use the HI7051M soil preparation solution.
| pH Range | -2.00 to 16.00 pH; -2.0 to 16.0 pH |
|---|---|
| pH Resolution | 0.01 pH; 0.1 pH |
| pH Accuracy | ±0.02 pH; ±0.1 pH |
| pH Calibration | automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18) |
| pH Temperature Compensation | automatic ‐5.0 to 105.0 °C/23.0 to 221.0 °F |
| pH CAL Check (electrode diagnostics) | probe condition indicator |
| mV Range | ±825 mV (pH‐mV) |
|---|---|
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV (pH‐mV) |
| Temperature Range | -5.0 to 105.0°C / 23.0 to 221.0°F |
|---|---|
| Temperature Resolution | 0.1°C / 0.1°F |
| Temperature Accuracy | ±0.5°C (up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F (outside) |
| pH Electrode | HI12923 glass body, pre-amplified pH electrode for soil measurement with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included) |
|---|---|
| Automatic Shut-Off | user selectable: after 8 min, 60 min or disabled |
| Battery Type/Life | 1.5V (3) AAA / approximately 1400 hours of continuous use; auto-off after 8 minutes of non-use |
| IP Protection | IP67 |
| Environment | 0 to 50°C (32 to 122°F); RH max 100% |
| Dimensions | 154 x 63 x 30 mm (6.1 x 2.5 x 1.2”) |
| Weight | 196 g (6.91 oz.) |
| Ordering Information | HI99121 is supplied with HI12923 pH electrode, HI721319 soil auger, HI7051M soil preparation solution (230 mL), HI70004 pH 4.01 buffer solution sachet (20 mL), HI70007 pH 7.01 buffer solution sachet (20 mL), HI700663 cleaning solution sachet for inorganic soil deposits (20 mL), HI700664 cleaning solution sachet for organic soil deposits (20 mL), 100 mL plastic beaker, batteries, instructions, and a hard carrying case |
Deskripsi
Jual Direct Soil Measurement pH Portable Meter Hanna – HI99121
DESKRIPSI : Direct Soil Measurement pH Portable Meter Hanna – HI99121
The HI99121 adalah alat ukur pH portabel yang sempurna untuk pengujian tanah. Dengan HI99121 dan HI12923 tanah langsung pra-amplifikasi pH dan probe suhu, pengguna dapat menguji pH tanah secara langsung atau setelah persiapan bubur tanah dengan air deionisasi. HI12923 memiliki tip berbentuk kerucut dan kasar yang dapat langsung dimasukkan ke tanah yang lembab atau lunak. Untuk tanah yang lebih keras, kit ini menyertakan auger plastik untuk melubangi tanah.
ATC
Kompensasi Suhu Otomatis
Otomatis, satu atau dua titik kalibrasi
Kalibrasi Dua Titik Otomatis
Tahan air
Tahan air
DETAIL
Features at-a-glance
- Automatic Temperature Compensation
- One or two-point automatic calibration
- BEPS – Alerts the user of low battery power that could adversely affect readings
- Compact, heavy-duty, and waterproof
- Battery % displayed on start-up
- HELP feature, displays messages on LCD
Note: Use the soil auger for stony ground to prevent damaging the glass probe.
For high accuracy and ensure the soil is wet use the HI7051M soil preparation solution.
For high accuracy and ensure the soil is wet use the HI7051M soil preparation solution.
| pH Range | -2.00 to 16.00 pH; -2.0 to 16.0 pH |
|---|---|
| pH Resolution | 0.01 pH; 0.1 pH |
| pH Accuracy | ±0.02 pH; ±0.1 pH |
| pH Calibration | automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18) |
| pH Temperature Compensation | automatic ‐5.0 to 105.0 °C/23.0 to 221.0 °F |
| pH CAL Check (electrode diagnostics) | probe condition indicator |
| mV Range | ±825 mV (pH‐mV) |
|---|---|
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV (pH‐mV) |
| Temperature Range | -5.0 to 105.0°C / 23.0 to 221.0°F |
|---|---|
| Temperature Resolution | 0.1°C / 0.1°F |
| Temperature Accuracy | ±0.5°C (up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F (outside) |
| pH Electrode | HI12923 glass body, pre-amplified pH electrode for soil measurement with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included) |
|---|---|
| Automatic Shut-Off | user selectable: after 8 min, 60 min or disabled |
| Battery Type/Life | 1.5V (3) AAA / approximately 1400 hours of continuous use; auto-off after 8 minutes of non-use |
| IP Protection | IP67 |
| Environment | 0 to 50°C (32 to 122°F); RH max 100% |
| Dimensions | 154 x 63 x 30 mm (6.1 x 2.5 x 1.2”) |
| Weight | 196 g (6.91 oz.) |
| Ordering Information | HI99121 is supplied with HI12923 pH electrode, HI721319 soil auger, HI7051M soil preparation solution (230 mL), HI70004 pH 4.01 buffer solution sachet (20 mL), HI70007 pH 7.01 buffer solution sachet (20 mL), HI700663 cleaning solution sachet for inorganic soil deposits (20 mL), HI700664 cleaning solution sachet for organic soil deposits (20 mL), 100 mL plastic beaker, batteries, instructions, and a hard carrying case |