• SANFIX IT-2400 Dual Lasers Infrared ThermometerWide Measurement Range : Infrared up to 2400C (4352F)
    High DS (Distance to Spot) Ratio = 100 : 1
    Dual Laser Points for the Target Spot Size
    Under Memory Mode, record and display the specific temperature with emissivity

    Specifications

    Model No. : IT-2400
    Description : IRT + Dual Lasers + Thermocouple Socket
    Measurement Range : 200 – 2400C (392 – 4352F)
    Operation Range : 0 – 50C (32 – 122F)
    Accuracy (Tobj=15-35C,Tamb=25C) : 1.0C (1.8F)
    Full Range Accuracy (Tamb=233C) : 2% of reading
    Resolution (-9.9 199.9C) : 0.1C/0.1F at -83.2 999.9(C/F), otherwise 1C/F
    Response Time (90%) : 1 sec
    Distance : Spot : 100 : 1
    Emissivity Range : 0.95 default adjustable 0.1 to 1 step .01
    Wave Length : 1.1 3.7m
    Dimensions : 60.6 x 207.5 x 233.8 mm (2.38 x 17 x 9.20 inch)
    Weight (Including Batteries) : 550 grams (19.4 oz)
    Thermocouple Probe : Small Socket, K type, 12 minutes auto Power Off
    Measurement Range : -64 to +1400C (-83.2 to +2552F) *Actual temperature range depends on the TC probe selected
    Probe Accuracy : 1% of reading (Test under Tamb=236C)
    Battery Life : Typ. 180, min 140 hours continuous use (Alkaline, without Laser and Back Light.)
    Battery Type : AA x 2
    Mode : Max, Min, Dif, Ave, Lock, Hi/Low Temp Alarm
    Memory : Detailed 24 Memories with Temperature & Emissivity
    Specification are subject to change without notice

Deskripsi

Jual Dual Lasers Infrared Thermometer SANFIX IT-2400

Deskripsi Dual Lasers Infrared Thermometer SANFIX IT-2400

SANFIX IT-2400 Dual Lasers Infrared Thermometer

Wide Measurement Range : Infrared up to 2400C (4352F)
High DS (Distance to Spot) Ratio = 100 : 1
Dual Laser Points for the Target Spot Size
Under Memory Mode, record and display the specific temperature with emissivity

Specifications

Model No. : IT-2400
Description : IRT + Dual Lasers + Thermocouple Socket
Measurement Range : 200 – 2400C (392 – 4352F)
Operation Range : 0 – 50C (32 – 122F)
Accuracy (Tobj=15-35C,Tamb=25C) : 1.0C (1.8F)
Full Range Accuracy (Tamb=233C) : 2% of reading
Resolution (-9.9 199.9C) : 0.1C/0.1F at -83.2 999.9(C/F), otherwise 1C/F
Response Time (90%) : 1 sec
Distance : Spot : 100 : 1
Emissivity Range : 0.95 default adjustable 0.1 to 1 step .01
Wave Length : 1.1 3.7m
Dimensions : 60.6 x 207.5 x 233.8 mm (2.38 x 17 x 9.20 inch)
Weight (Including Batteries) : 550 grams (19.4 oz)
Thermocouple Probe : Small Socket, K type, 12 minutes auto Power Off
Measurement Range : -64 to +1400C (-83.2 to +2552F) *Actual temperature range depends on the TC probe selected
Probe Accuracy : 1% of reading (Test under Tamb=236C)
Battery Life : Typ. 180, min 140 hours continuous use (Alkaline, without Laser and Back Light.)
Battery Type : AA x 2
Mode : Max, Min, Dif, Ave, Lock, Hi/Low Temp Alarm
Memory : Detailed 24 Memories with Temperature & Emissivity
* Specification are subject to change without notice