Jual edge® Multiparameter pH Meter Hanna – HI2020
SPESIFIKASI : edge® Multiparameter pH Meter Hanna – HI2020
DETAIL
| pH Range | -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV |
|---|---|
| pH Resolution | 0.001 pH, 0.01 pH, 0.1 mV |
| pH Accuracy | ±0.002 pH, ±0.01 pH, ±0.2 mV |
| pH Calibration | 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01 |
| pH Temperature Compensation | ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F* |
| pH CAL Check (electrode diagnostics) | Probe condition, response time, glass and reference junction diagnostics ( HI 11311 & HI 12301 only) |
| EC Range | 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)** |
|---|---|
| EC Resolution | 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm |
| EC Accuracy | ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater) |
| EC Calibration | 1 point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm |
| TDS Range | 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**, with 0.80 conversion factor |
| TDS Resolution | 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
| TDS Accuracy | ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) |
| TDS Calibration | through EC calibration |
| EC/TDS Temperature Compensation | ATC (0.0 to 100.0ºC; 32.0 to 212.0 °F), NoTC |
| Temperature Correction Coefficient | 0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C |
| EC to TDS Conversion Factor | 0.40 to 0.80 |
| Salinity (% NaCl) Range | 0.0 to 400.0% NaCl*** |
|---|---|
| Salinity (% NaCl) Resolution | 0.1% NaCl |
| Salinity (% NaCl) Accuracy | ±1% of reading (@25ºC/77ºF) |
| Salinity (% NaCl) Calibration | 1 point with HI 7037L 100% NaCl sea water standard |
| Salinity (PSU) Range | 2.00 to 42.00 PSU*** |
| Salinity (PSU) Resolution | 0.01 PSU |
| Salinity (PSU) Accuracy | ±1% of reading (@25ºC/77ºF) |
| Salinity (PSU) Calibration | through EC calibration |
| Salinity Range | 0.0 to 80.0 g/L*** |
| Salinity Resolution (ppt) | 0.01 g/L |
| Salinity Accuracy (ppt) | ±1% of reading (@25ºC/77ºF) |
| Salinity Calibration (ppt) | through EC calibration |
| Oxygen, Dissolved Range | 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation |
|---|---|
| Oxygen, Dissolved Resolution | 0.01 ppm, 0.1% saturation |
| Oxygen, Dissolved Accuracy | ±1 digit, ±1.5% of reading |
| Oxygen, Dissolved Calibration | one or two points at 0% (HI 7040 solution) and 100% (in air) |
| Oxygen, Dissolved Temperature Compensation | ATC: 0 to 50 ºC; 32.0 to 122.0 °F |
| Salinity Compensation | 0 to 40 g/L (with 1 g/L resolution) |
| Altitude Compensation | -500 to 4000 m (with 100 m resolution) |
| Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F |
|---|---|
| Temperature Resolution | 0.1 °C, 0.1 °F |
| Temperature Accuracy | ±0.5 °C, ±0.9 °F |
| pH Electrode | HI11310 pH electrode (included) |
|---|---|
| Logging Type | Manual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots) |
| Logging Memory | up to 1000*** records |
| Connectivity | 1 micro USB port for charging and PC connectivity, 1 USB port for storage |
| Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
| Power Supply | 230VAC to 5 VDC adapter (included) |
| Environment | 0 to 50°C (32 to 122°F), RH max 95% non-condensing |
| Dimensions | 202 x 140 x 12.7mm (8” x 5.5” x 0.5”) |
| Weight | 250 g (8.82 oz) |
| Ordering Information | HI2020 pH kit includes: HI11310 glass body, refillable pH electrode with temperature sensor, pH 4 buffer solution sachets, pH 7 buffer solution sachets, pH 10 buffer solution sachets, electrode cleaning solution sachets,USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, instruction manual, and quality certificate. |
| Notes | * temperature limits will be reduced to actual probe/sensor limits ** with temperature compensation function disabled *** for standard mode only † pH 3.00 is only visible when using specific pH electrodes and will replace 4.01pH buffer |
Deskripsi
Jual edge® Multiparameter pH Meter Hanna – HI2020
DESKRIPSI : edge® Multiparameter pH Meter Hanna – HI2020
Hanna Instruments dengan bangga memperkenalkan pH meter paling inovatif di dunia: edge®. desain inovatif edge adalah puncak dari visi Hanna, kemampuan desain, produksi terintegrasi dan R&D kelas dunia. Meter tepi hanya setebal 0,5 ”namun kaya fitur untuk mengakomodasi kebutuhan sejumlah besar pelanggan. Bagi mereka yang lebih suka operasi yang sangat sederhana ada operasi mode dasar dengan menu dan opsi yang disederhanakan. Bagi mereka yang memerlukan fitur-fitur canggih ada mode operasi standar berfitur lengkap. Kit pH tepi HI2020 dapat ditingkatkan kapan saja dengan probe tambahan untuk mengukur Konduktivitas atau Oksigen Terlarut.
DETAIL
| pH Range | -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV |
|---|---|
| pH Resolution | 0.001 pH, 0.01 pH, 0.1 mV |
| pH Accuracy | ±0.002 pH, ±0.01 pH, ±0.2 mV |
| pH Calibration | 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01 |
| pH Temperature Compensation | ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F* |
| pH CAL Check (electrode diagnostics) | Probe condition, response time, glass and reference junction diagnostics ( HI 11311 & HI 12301 only) |
| EC Range | 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)** |
|---|---|
| EC Resolution | 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm |
| EC Accuracy | ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater) |
| EC Calibration | 1 point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm |
| TDS Range | 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**, with 0.80 conversion factor |
| TDS Resolution | 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
| TDS Accuracy | ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) |
| TDS Calibration | through EC calibration |
| EC/TDS Temperature Compensation | ATC (0.0 to 100.0ºC; 32.0 to 212.0 °F), NoTC |
| Temperature Correction Coefficient | 0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C |
| EC to TDS Conversion Factor | 0.40 to 0.80 |
| Salinity (% NaCl) Range | 0.0 to 400.0% NaCl*** |
|---|---|
| Salinity (% NaCl) Resolution | 0.1% NaCl |
| Salinity (% NaCl) Accuracy | ±1% of reading (@25ºC/77ºF) |
| Salinity (% NaCl) Calibration | 1 point with HI 7037L 100% NaCl sea water standard |
| Salinity (PSU) Range | 2.00 to 42.00 PSU*** |
| Salinity (PSU) Resolution | 0.01 PSU |
| Salinity (PSU) Accuracy | ±1% of reading (@25ºC/77ºF) |
| Salinity (PSU) Calibration | through EC calibration |
| Salinity Range | 0.0 to 80.0 g/L*** |
| Salinity Resolution (ppt) | 0.01 g/L |
| Salinity Accuracy (ppt) | ±1% of reading (@25ºC/77ºF) |
| Salinity Calibration (ppt) | through EC calibration |
| Oxygen, Dissolved Range | 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation |
|---|---|
| Oxygen, Dissolved Resolution | 0.01 ppm, 0.1% saturation |
| Oxygen, Dissolved Accuracy | ±1 digit, ±1.5% of reading |
| Oxygen, Dissolved Calibration | one or two points at 0% (HI 7040 solution) and 100% (in air) |
| Oxygen, Dissolved Temperature Compensation | ATC: 0 to 50 ºC; 32.0 to 122.0 °F |
| Salinity Compensation | 0 to 40 g/L (with 1 g/L resolution) |
| Altitude Compensation | -500 to 4000 m (with 100 m resolution) |
| Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F |
|---|---|
| Temperature Resolution | 0.1 °C, 0.1 °F |
| Temperature Accuracy | ±0.5 °C, ±0.9 °F |
| pH Electrode | HI11310 pH electrode (included) |
|---|---|
| Logging Type | Manual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots) |
| Logging Memory | up to 1000*** records |
| Connectivity | 1 micro USB port for charging and PC connectivity, 1 USB port for storage |
| Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
| Power Supply | 230VAC to 5 VDC adapter (included) |
| Environment | 0 to 50°C (32 to 122°F), RH max 95% non-condensing |
| Dimensions | 202 x 140 x 12.7mm (8” x 5.5” x 0.5”) |
| Weight | 250 g (8.82 oz) |
| Ordering Information | HI2020 pH kit includes: HI11310 glass body, refillable pH electrode with temperature sensor, pH 4 buffer solution sachets, pH 7 buffer solution sachets, pH 10 buffer solution sachets, electrode cleaning solution sachets,USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, instruction manual, and quality certificate. |
| Notes | * temperature limits will be reduced to actual probe/sensor limits ** with temperature compensation function disabled *** for standard mode only † pH 3.00 is only visible when using specific pH electrodes and will replace 4.01pH buffer |