Specifications
Range : 0.00 to 14.00 pH
Resolution : 0.01 pH
Accuracy (@25°C/77°F) : ±0.02 pH
Calibration : manual, 2 points through offset and slope trimmers
Dosing Relay : maximum 2A (fuse protected), 250 Vac, 30 VDC
Dosing Selection : acid or alkaline
contact open=acid dosage=relay ON if measurement > setpoint
contact closed=alkaline dosage=relay ON if measurement < setpoint
Setpoint : adjustable from 0 to 14 pH
Overtime : adjustable, typically from 5 to approximately 30 minutes
Input Impedance : 10¹² Ohm
Analog Output : 4 to 20 mA, accuracy ±0.20 mA, 500 ¥ maximum load
Power Supply : BL931700-0: 12 VDC adapter (included);
BL931700-1: 115/230 VAC; 50/60Hz
Dimensions : 83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’)
Weight : BL931700-0: 200 g (7.1 oz.);
BL931700-1: 300 g (10.6 oz.)
Ordering Information : BL931700-0 (12 VDC) and BL931700-1 ( 115V) are supplied with mounting brackets, transparent cover and instruction manual.
Deskripsi
Mini pH Controller HANNA BL931700
- Enhanced Accuracy & Precision
- The BL931700 model offers a manual two-point calibration with pH values displayed out to two decimal places.
- External Disabling Feature
- A normally open contact may connect to a level controller or flow monitor. This safety feature may be used to prevent continuous dosing in the event of specific or undesired system conditions.
- Adjustable Dosing Relay
- The BL931700 features a dosing relay which may be configured to dose above or below a user programmable pH setpoint.
- Selectable Overdose Protection
- The mini controller may be programmed to deactivate a valve, pump, or connected device if its activation continues over a selected time; adjustable from 5 to 30 minutes.
- Selectable Control Override
- With the flick of a switch, normal “Auto” operation may be overridden turning your connected device “Off” from operation or always “On.”
- Analog Output Communication
- The BL931700 features a 4 – 20 mA analog output for connection to a data logger, chart recorder, or other device.
- Matching Pin Connection
- An included matching pin option helps protect the sensor from ground loop effects that may lead to erratic readings or system damage.
- Fuse Protected Dosing Contacts
- The mini controller is protected for up to a 2A load from the connected pump or device.
- Easy Peripheral Connection
- Quick-connect terminal blocks provide for easy connection to power, communication, dosing control, or sensors.