Jual Plating pH Portable Meter Hanna- HI99131

SPESIFIKASI : Plating pH Portable Meter Hanna- HI99131

DETAIL

 

Features at-a-glance

  • Automatic Temperature Compensation
  • One or two-point automatic calibration
  • BEPS – Alerts the user of low battery power that could adversely affect readings
  • Compact, heavy-duty, and waterproof
  • Battery % displayed on start-up
  • HELP feature, displays tutorial messages on LCD
pH Range -2.00 to 16.00 pH; -2.0 to 16.0 pH
pH Resolution 0.01 pH; 0.1 pH
pH Accuracy ±0.02 pH; ±0.1 pH;
pH Calibration automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
pH Temperature Compensation Automatic ‐5.0 to 105.0 °C/23.0 to 221.0 °F
pH CAL Check (electrode diagnostics) Probe condition indicator
mV Range ±825 mV (pH‐mV)
mV Resolution 1 mV (pH‐mV)
mV Accuracy ±1 mV (pH‐mV)
Temperature Range -5.0 to 105.0°C / 23.0 to 221.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C (up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F (outside)
pH Electrode HI629113 titanium body, pre-amplified pH probe with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included)
Automatic Shut-Off user selectable: after 8 min, 60 min or disabled
Battery Type/Life 1.5V (3) AAA / approximately 1400 hours of continuous use
IP Protection IP67
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)
Weight 205 g (7.2 oz.)
Ordering Information HI99131 is supplied with HI629113 pH probe, HI70004 pH 4.01 buffer solution sachet (1), HI70007 pH 7.01 buffer solution sachet (1), HI700601 electrode cleaning solution sachets (2 x 20 mL), 100 ml beaker, batteries, instructions, calibration certificates for the meter and probe, and rugged carrying case.

 

Deskripsi

Jual Plating pH Portable Meter Hanna- HI99131

DESKRIPSI : Plating pH Portable Meter Hanna- HI99131

The HI99131 adalah pH tahan air, portabel dan pengukur suhu yang dirancang khusus untuk digunakan dalam rendaman mandi. Penyelidik pH junction ganda junction HI-629113 pre-amplified memiliki ujung datar yang tersembunyi yang mudah dibersihkan dan mencegah benda padat dalam larutan terkumpul pada sensor. Tubuh titanium dari HI629113 berfungsi sebagai pin pencocokan potensial untuk meningkatkan stabilitas pembacaan dan memperpanjang usia sensor.

ATC

Kompensasi Suhu Otomatis
Otomatis, satu atau dua titik kalibrasi

Kalibrasi Dua Titik Otomatis
Tahan air

Tahan air
DETAIL

Features at-a-glance

  • Automatic Temperature Compensation
  • One or two-point automatic calibration
  • BEPS – Alerts the user of low battery power that could adversely affect readings
  • Compact, heavy-duty, and waterproof
  • Battery % displayed on start-up
  • HELP feature, displays tutorial messages on LCD
pH Range -2.00 to 16.00 pH; -2.0 to 16.0 pH
pH Resolution 0.01 pH; 0.1 pH
pH Accuracy ±0.02 pH; ±0.1 pH;
pH Calibration automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
pH Temperature Compensation Automatic ‐5.0 to 105.0 °C/23.0 to 221.0 °F
pH CAL Check (electrode diagnostics) Probe condition indicator
mV Range ±825 mV (pH‐mV)
mV Resolution 1 mV (pH‐mV)
mV Accuracy ±1 mV (pH‐mV)
Temperature Range -5.0 to 105.0°C / 23.0 to 221.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C (up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F (outside)
pH Electrode HI629113 titanium body, pre-amplified pH probe with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included)
Automatic Shut-Off user selectable: after 8 min, 60 min or disabled
Battery Type/Life 1.5V (3) AAA / approximately 1400 hours of continuous use
IP Protection IP67
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)
Weight 205 g (7.2 oz.)
Ordering Information HI99131 is supplied with HI629113 pH probe, HI70004 pH 4.01 buffer solution sachet (1), HI70007 pH 7.01 buffer solution sachet (1), HI700601 electrode cleaning solution sachets (2 x 20 mL), 100 ml beaker, batteries, instructions, calibration certificates for the meter and probe, and rugged carrying case.